Availability: | |
---|---|
Quantity: | |
TP-96G
TOP
TOP INSTRUMENT 96 Holes PCR System is the core equipment to complete PCR reaction. It can quickly and specifically amplify any target DNA in vitro. It is a major development of molecular biology and this technology has greatly promoted the progress of genetic discovery and made the relevant decisive technologies simple and repeatable.
Characteristic:
Optional temperature control mode.
Fast temperature change rate to save experimental time.
Maximum 30 ℃ gradient (c-96 and c-32 instruments are not applicable).
Hot start function .
The hot cover pressure is adjustable to prevent liquid volatilization, so as to adapt to various PCR pipes.
Excellent temperature uniformity to ensure the best experimental results.
The latest generation of 7-inch touch screen, curve graphics display program.
Power failure automatic protection.
The latest USB flash disk interface, download the program through USB flash disk.
Imported core parts with guaranteed quality and service life.
TOP INSTRUMENT 96 Holes PCR System is the core equipment to complete PCR reaction. It can quickly and specifically amplify any target DNA in vitro. It is a major development of molecular biology and this technology has greatly promoted the progress of genetic discovery and made the relevant decisive technologies simple and repeatable.
Characteristic:
Optional temperature control mode.
Fast temperature change rate to save experimental time.
Maximum 30 ℃ gradient (c-96 and c-32 instruments are not applicable).
Hot start function .
The hot cover pressure is adjustable to prevent liquid volatilization, so as to adapt to various PCR pipes.
Excellent temperature uniformity to ensure the best experimental results.
The latest generation of 7-inch touch screen, curve graphics display program.
Power failure automatic protection.
The latest USB flash disk interface, download the program through USB flash disk.
Imported core parts with guaranteed quality and service life.
Temperature rise and fall technolog | the latest generation of semiconductor technology | |
Sample table capacity | 0.2ml*96 hole or 0.5ml*96 hole or 0.2ml*96 hole + 0.5ml*77 hole, in-situ tray | |
U disk functio | unlimited download of program through U disk | |
Communication interfac | USB2.0 RS232 | |
Sample table temperature | 0-100℃ | |
Heating Rate | 4℃/s | |
Cooling Rate | 4℃/s | |
Maximum temperature points | 40, multiple nested cycle | |
Temperature uniformity of sample table | ≤± 0.2℃ (30 seconds after reaching the set temperature point) | |
Temperature accuracy of sample table | ≤± 0.1℃ (30℃ ~ 100℃) | |
Program storage | the instrument can store 20000 programs, and unlimited programs can be downloaded through USB flash disk | |
Accuracy of gradient temperature | ≤± 0.1 ℃ (35 ℃ - 99.9 ℃) | |
Gradient temperature uniformit | ≤± 0.2 ℃ (30 seconds after reaching the set temperature point) | |
Temperature control mode | analog tube + sample table | |
Gradient range | 30 ℃ ~ 99.9 ℃ | |
Gradient Temp. difference range | maximum 30 ℃ | |
Gradient temperature point distribution | 12 columns (vertical direction) | |
Time increment/decrement | 1 Sec - 120 Sec | |
Temp. increment/decrement | 0.1-10.0℃ | |
Adjustable temperature change speed | Yes | |
Language | both Chinese and English | |
Power off protection | Yes | |
4℃ insulation: | Yes | |
LCD | 7 inch, curve graphic display program | |
Heat cover height | stepless adjustable, pressure adaptive PCR tube and tray | |
Heat cover temperature | 30 ℃ ~ 105 ℃ adjustable | |
Automatic closing function of hot cover | when the temperature of sample table is lower than 30 ℃, the hot cover will close automatically. At the end of the program, the hot cover closes automatically | |
Input power | 600 W |
Temperature rise and fall technolog | the latest generation of semiconductor technology | |
Sample table capacity | 0.2ml*96 hole or 0.5ml*96 hole or 0.2ml*96 hole + 0.5ml*77 hole, in-situ tray | |
U disk functio | unlimited download of program through U disk | |
Communication interfac | USB2.0 RS232 | |
Sample table temperature | 0-100℃ | |
Heating Rate | 4℃/s | |
Cooling Rate | 4℃/s | |
Maximum temperature points | 40, multiple nested cycle | |
Temperature uniformity of sample table | ≤± 0.2℃ (30 seconds after reaching the set temperature point) | |
Temperature accuracy of sample table | ≤± 0.1℃ (30℃ ~ 100℃) | |
Program storage | the instrument can store 20000 programs, and unlimited programs can be downloaded through USB flash disk | |
Accuracy of gradient temperature | ≤± 0.1 ℃ (35 ℃ - 99.9 ℃) | |
Gradient temperature uniformit | ≤± 0.2 ℃ (30 seconds after reaching the set temperature point) | |
Temperature control mode | analog tube + sample table | |
Gradient range | 30 ℃ ~ 99.9 ℃ | |
Gradient Temp. difference range | maximum 30 ℃ | |
Gradient temperature point distribution | 12 columns (vertical direction) | |
Time increment/decrement | 1 Sec - 120 Sec | |
Temp. increment/decrement | 0.1-10.0℃ | |
Adjustable temperature change speed | Yes | |
Language | both Chinese and English | |
Power off protection | Yes | |
4℃ insulation: | Yes | |
LCD | 7 inch, curve graphic display program | |
Heat cover height | stepless adjustable, pressure adaptive PCR tube and tray | |
Heat cover temperature | 30 ℃ ~ 105 ℃ adjustable | |
Automatic closing function of hot cover | when the temperature of sample table is lower than 30 ℃, the hot cover will close automatically. At the end of the program, the hot cover closes automatically | |
Input power | 600 W |