Availability: | |
---|---|
Quantity: | |
T-840U
TOP
T-840U Horizontal Laminar Flow Clean Bench is a kind of clean bench widely used in medical treatment, chemical experiment, electron, precise machinery, instrument, apparatus, medical preparation, operating room, foodstuff, drinks, daily-use cosmetic, stock raising and aviation, as well as providing germfree dustless clean environment.
Characteristic:
Arbitrary positioning sliding door system is adopted.
The shell is welded by cold-rolled plate, the surface is electrostatically sprayed, and the work surface is SUS304 brushed stainless steel, which is corrosion-resistant and easy to clean.
Safety interlocking of lighting and sterilization system, and UV lamp timing function (except 1BU and 1CU).
Digital display LCD control interface, more humanized design.
The vertical quasi-closed table top and the formation of the downflow air curtain in the operation room can effectively prevent the external gas from entering and clean the operation area.
Equipped with a HEPA high-efficiency air filter, and a primary filter for preliminary filtration, which can effectively extend the high-efficiency filter.
T-840U Horizontal Laminar Flow Clean Bench is a kind of clean bench widely used in medical treatment, chemical experiment, electron, precise machinery, instrument, apparatus, medical preparation, operating room, foodstuff, drinks, daily-use cosmetic, stock raising and aviation, as well as providing germfree dustless clean environment.
Characteristic:
Arbitrary positioning sliding door system is adopted.
The shell is welded by cold-rolled plate, the surface is electrostatically sprayed, and the work surface is SUS304 brushed stainless steel, which is corrosion-resistant and easy to clean.
Safety interlocking of lighting and sterilization system, and UV lamp timing function (except 1BU and 1CU).
Digital display LCD control interface, more humanized design.
The vertical quasi-closed table top and the formation of the downflow air curtain in the operation room can effectively prevent the external gas from entering and clean the operation area.
Equipped with a HEPA high-efficiency air filter, and a primary filter for preliminary filtration, which can effectively extend the high-efficiency filter.
Cleaning level | Grade 100≥0.5μM (209E U.S. Federal) |
Number of bacteria | ≤0.5per utensil.hour (90mm utensil) |
The average wind speed | 0.25~0.45m/s |
Noise | ≤62dB (A) |
Half ventilation peak value | ≤5μm (XYZ direction) |
Illumination | ≥300LX |
Power supply | AC, 220V/50Hz |
Max. power consumption | 400W |
Weight | 150kg |
Dimension of working area (W1*D1*H1) | 700*560*580mm |
Overall dimension (W*D*H) | 855*765*1765mm |
Suited number | single-single |
Efficient filter specifications and quantities | 695*600*38*① |
Specification and number of fluorescent lamp or UV lamp of ultraviolet lights | 20W*①/20W*① |
Cleaning level | Grade 100≥0.5μM (209E U.S. Federal) |
Number of bacteria | ≤0.5per utensil.hour (90mm utensil) |
The average wind speed | 0.25~0.45m/s |
Noise | ≤62dB (A) |
Half ventilation peak value | ≤5μm (XYZ direction) |
Illumination | ≥300LX |
Power supply | AC, 220V/50Hz |
Max. power consumption | 400W |
Weight | 150kg |
Dimension of working area (W1*D1*H1) | 700*560*580mm |
Overall dimension (W*D*H) | 855*765*1765mm |
Suited number | single-single |
Efficient filter specifications and quantities | 695*600*38*① |
Specification and number of fluorescent lamp or UV lamp of ultraviolet lights | 20W*①/20W*① |