Availability: | |
---|---|
Quantity: | |
PYD-0956A
TOP
Automated Houillon Viscosity Tester is designed and manufactured according to the standard SH / T0956-2017 "Determination of Kinematic Viscosity of Transparent and Opaque Liquids by Folded Tube Automatic Viscometer" and ASTM D7279-14A "Standard Test method For Kinematic Viscosity of Transparent and Opaque Liquids by Automated Houillon Viscometer", It is suitable for the determination of kinematic viscosity of transparent and opaque liquids, including base oil, blended lubricating oil, biodiesel, Biodiesel Blended fuel, residual fuel oil, marine oil, etc.
Characteristic:
Full automatic control, one key start detection, the test process includes measurement, cleaning, drying, test results calculation and data storage. It will stop automatically after the test.
The measuring speed is fast, the fastest measuring time is no more than 30s, and the average measuring time is less than 3 minutes.
The instrument can accurately control the sample measurement conditions and ensure the accuracy of the measurement data.
The instrument has dual solvent automatic cleaning function, which can quickly clean the folded tube viscometer, and the consumption of cleaning agent in one cleaning process is not more than 15ml.
The instrument has dual functions of over temperature protection and dry burning prevention.
It is convenient and quick to replace the folded tube viscometer. The viscometer can be replaced without draining the bath liquid. The replacement can be completed within 2 minutes.
Automated Houillon Viscosity Tester is designed and manufactured according to the standard SH / T0956-2017 "Determination of Kinematic Viscosity of Transparent and Opaque Liquids by Folded Tube Automatic Viscometer" and ASTM D7279-14A "Standard Test method For Kinematic Viscosity of Transparent and Opaque Liquids by Automated Houillon Viscometer", It is suitable for the determination of kinematic viscosity of transparent and opaque liquids, including base oil, blended lubricating oil, biodiesel, Biodiesel Blended fuel, residual fuel oil, marine oil, etc.
Characteristic:
Full automatic control, one key start detection, the test process includes measurement, cleaning, drying, test results calculation and data storage. It will stop automatically after the test.
The measuring speed is fast, the fastest measuring time is no more than 30s, and the average measuring time is less than 3 minutes.
The instrument can accurately control the sample measurement conditions and ensure the accuracy of the measurement data.
The instrument has dual solvent automatic cleaning function, which can quickly clean the folded tube viscometer, and the consumption of cleaning agent in one cleaning process is not more than 15ml.
The instrument has dual functions of over temperature protection and dry burning prevention.
It is convenient and quick to replace the folded tube viscometer. The viscometer can be replaced without draining the bath liquid. The replacement can be completed within 2 minutes.
Power supply | AC220V, 50Hz |
Bath tube volume | 10L |
Measurement range | 3~3000mm2/s |
Sample qty | 0.5~1mL |
Time control accuracy | 0.01℃ |
Timing accuracy | 0.01s |
Test time | within 3 minutes (the whole process of measurement, cleaning and drying is within 10 minutes) |
Temperature control range | room temperature ~ 120 ℃ (When temperature is below room temperature, extra cold external circulation is prepared) |
Repeatability | ≤0.68% |
Detection unit | Double folded tube viscometer (single tube three group laser detection) |
Operation interface | Industrial grade 10.4-inch LCD |
Total power consumption | ≤1400W |
Working temperature | 10~30℃ |
Relative humidity | ≤80% |
Dimension | 650*500*600mm |
Power supply | AC220V, 50Hz |
Bath tube volume | 10L |
Measurement range | 3~3000mm2/s |
Sample qty | 0.5~1mL |
Time control accuracy | 0.01℃ |
Timing accuracy | 0.01s |
Test time | within 3 minutes (the whole process of measurement, cleaning and drying is within 10 minutes) |
Temperature control range | room temperature ~ 120 ℃ (When temperature is below room temperature, extra cold external circulation is prepared) |
Repeatability | ≤0.68% |
Detection unit | Double folded tube viscometer (single tube three group laser detection) |
Operation interface | Industrial grade 10.4-inch LCD |
Total power consumption | ≤1400W |
Working temperature | 10~30℃ |
Relative humidity | ≤80% |
Dimension | 650*500*600mm |