Availability: | |
---|---|
Quantity: | |
TM1224
TOP
Hematocrit Centrifuge is used for determination of erythrocyte fractions in blood as well as micro solution separations. It provides hematocrit values (HCT) for testing in biochemistry, immunity, genetics, blood separation and for general. It has special applications for the photometric determination of bilirubin content in neonate blood samples. It is suitable for extraction of DNA and RNA.
Characteristic:
Speed range of 200-12000 rpm Precise and independent.
control of speed and time.
Easy operation with intuitive menu and LCD display.
Maintenance-free brushless DC motor.
Pulse operation for fast and convenient quick spins.
Advance features include speed/RCF switch; short-time run function; audible alert function.
Safety features include door interlock, overspeed detector; over-temperature detector; automatic internal diagnosis and automatic rotor identification.
Hematocrit Centrifuge is used for determination of erythrocyte fractions in blood as well as micro solution separations. It provides hematocrit values (HCT) for testing in biochemistry, immunity, genetics, blood separation and for general. It has special applications for the photometric determination of bilirubin content in neonate blood samples. It is suitable for extraction of DNA and RNA.
Characteristic:
Speed range of 200-12000 rpm Precise and independent.
control of speed and time.
Easy operation with intuitive menu and LCD display.
Maintenance-free brushless DC motor.
Pulse operation for fast and convenient quick spins.
Advance features include speed/RCF switch; short-time run function; audible alert function.
Safety features include door interlock, overspeed detector; over-temperature detector; automatic internal diagnosis and automatic rotor identification.
Max. Speed [rpm] | 500-12000rpm, increment: 100rpm |
Max. RCF [*g] | 13680*g |
Speed Accuracy [rpm] | ±100 |
Rotor Capacity | 1 type rotor, Hhematocrit rotor: 24*capillary tubes (12000rpm) |
Run Time | 10sec-99min-HOLD (Continuous operation) |
Driving Motor | Brushless DC motor |
Safety Devices | Door interlock |
Power | Single-phase, 200V-240V, 50Hz/60Hz, 5A; 380W |
Noise level [dB] | ≤60 |
Acceleration | 40s↑40s↓ |
Dimensions [mm] | (L)280*(W)364*(H)213 |
Weight | 10kg |
Additional Features | Speed/RCF switch; Short-time run function; sound-alert function |
Max. Speed [rpm] | 500-12000rpm, increment: 100rpm |
Max. RCF [*g] | 13680*g |
Speed Accuracy [rpm] | ±100 |
Rotor Capacity | 1 type rotor, Hhematocrit rotor: 24*capillary tubes (12000rpm) |
Run Time | 10sec-99min-HOLD (Continuous operation) |
Driving Motor | Brushless DC motor |
Safety Devices | Door interlock |
Power | Single-phase, 200V-240V, 50Hz/60Hz, 5A; 380W |
Noise level [dB] | ≤60 |
Acceleration | 40s↑40s↓ |
Dimensions [mm] | (L)280*(W)364*(H)213 |
Weight | 10kg |