P9012C
TOP
P9012C Platinum Cobalt Colorimeter adopts the platinum cobalt standard colorimetric method to determine the color produced by substances in a dissolved state, and the instrument uses platinum cobalt chromaticity as the unit of measurement. It can be widely used for platinum cobalt color determination in pure water plants, water plants, domestic sewage treatment plants, beverage plants, environmental protection departments, industrial water, liquor and pharmaceutical industries, epidemic prevention departments, hospitals, chemical products and other departments.
Characteristic:
Microcomputer system configuration, touch keyboard, standard serial RS232 communication interface, compatible with printer
LCD backlit display screen, capable of clearly displaying date, time, measurement values, and measurement units
Programmable calibration standard values can be set arbitrarily, fast and automatic multi-point calibration can be performed, and 1-7 point automatic calibration can be selected quickly and arbitrarily
Built in clock memory storage system, real-time storage of measurement and calibration data, capable of long-term storage and retrieval of the last 20 sets of measurement data
Equipped with a turbidity compensation system, it effectively avoids interference caused by suspended particles in the sample and can accurately reflect the concept of chromaticity
Self diagnostic information prompt, direct reading chromaticity value, 100000 hours long lifespan high-intensity light source, maintenance free long-term use
P9012C Platinum Cobalt Colorimeter adopts the platinum cobalt standard colorimetric method to determine the color produced by substances in a dissolved state, and the instrument uses platinum cobalt chromaticity as the unit of measurement. It can be widely used for platinum cobalt color determination in pure water plants, water plants, domestic sewage treatment plants, beverage plants, environmental protection departments, industrial water, liquor and pharmaceutical industries, epidemic prevention departments, hospitals, chemical products and other departments.
Characteristic:
Microcomputer system configuration, touch keyboard, standard serial RS232 communication interface, compatible with printer
LCD backlit display screen, capable of clearly displaying date, time, measurement values, and measurement units
Programmable calibration standard values can be set arbitrarily, fast and automatic multi-point calibration can be performed, and 1-7 point automatic calibration can be selected quickly and arbitrarily
Built in clock memory storage system, real-time storage of measurement and calibration data, capable of long-term storage and retrieval of the last 20 sets of measurement data
Equipped with a turbidity compensation system, it effectively avoids interference caused by suspended particles in the sample and can accurately reflect the concept of chromaticity
Self diagnostic information prompt, direct reading chromaticity value, 100000 hours long lifespan high-intensity light source, maintenance free long-term use
Measuring range | 0 ~ 50, 0 ~ 500 degrees (Hazen, Pt Co, PCU, milligrams of platinum/liter) |
Minimum indication | 0.1 degrees |
BIndication error | ± 5% F.S |
Repeatability | ≤1.5% |
Power supply | AC 220V ±10% 50Hz/5W |
Characters | Desktop microcomputer configuration, high precision, with multi-point linear correction |
Measuring range | 0 ~ 50, 0 ~ 500 degrees (Hazen, Pt Co, PCU, milligrams of platinum/liter) |
Minimum indication | 0.1 degrees |
BIndication error | ± 5% F.S |
Repeatability | ≤1.5% |
Power supply | AC 220V ±10% 50Hz/5W |
Characters | Desktop microcomputer configuration, high precision, with multi-point linear correction |