Availability: | |
---|---|
Quantity: | |
PCOD-810
TOP
This Portable COD Analyzer is the use of sealed catalytic digestion, and then colorimetric measurements. The instrument uses advanced, narrowband interference technology.
Characteristic:
Analyzer apart with digestion device, does not affect measurement accuracy. PID automatic temperature control, automatic timing.
High-performance ultra-low power 16-bit microcontroller, standby time of the instrument is up to six months or more.
Operation save time, COD digestion just 10min.
Cold light, narrowband interference optical system, good optical stability.
Data power protection.
COD can be saved for each standard curve 50 and 199 measured values (with a time label with the year, month, day, hour, minute and second values of COD, absorbance and transmittance)
With a USB port, you can join the computer to record read.
LCD large-screen LCD for easy and intuitive operation.
Host chassis with molded ABS material, IP65 design, waterproof and dustproof performance.
With calibration tube function, eliminating the optical differences digestion tubes, to ensure accuracy.
Optional printing function and emergency backup battery.
Packing List:
Name | Quantity | Name | Quantity |
Host | 1 | Digestion instrument | 1 |
Digestion colorimetric tubes | 10 | Tube rack | 1 |
Cod reagent | 1 set | Digestion shield | 1 |
Portable case | 1 | AC / DC converter (220V / 12V) | 1 |
Operation manual | 1 | Product certificate | 1 |
Warranty card | 1 | Car cigarette lighter cable | 1 |
This Portable COD Analyzer is the use of sealed catalytic digestion, and then colorimetric measurements. The instrument uses advanced, narrowband interference technology.
Characteristic:
Analyzer apart with digestion device, does not affect measurement accuracy. PID automatic temperature control, automatic timing.
High-performance ultra-low power 16-bit microcontroller, standby time of the instrument is up to six months or more.
Operation save time, COD digestion just 10min.
Cold light, narrowband interference optical system, good optical stability.
Data power protection.
COD can be saved for each standard curve 50 and 199 measured values (with a time label with the year, month, day, hour, minute and second values of COD, absorbance and transmittance)
With a USB port, you can join the computer to record read.
LCD large-screen LCD for easy and intuitive operation.
Host chassis with molded ABS material, IP65 design, waterproof and dustproof performance.
With calibration tube function, eliminating the optical differences digestion tubes, to ensure accuracy.
Optional printing function and emergency backup battery.
Packing List:
Name | Quantity | Name | Quantity |
Host | 1 | Digestion instrument | 1 |
Digestion colorimetric tubes | 10 | Tube rack | 1 |
Cod reagent | 1 set | Digestion shield | 1 |
Portable case | 1 | AC / DC converter (220V / 12V) | 1 |
Operation manual | 1 | Product certificate | 1 |
Warranty card | 1 | Car cigarette lighter cable | 1 |
Measurement range: | COD: 5~2000mg/L, measured over dilution | Indication error: | COD: ≤ ± 5 % |
Repeatability: | ≤3% | Anti-chlorine interference: | ≤2000mg/L |
Temperature control accuracy: | ±1 °C | Temperature control system: | can be set at room temperature ~180°C, COD digestion temperature is 165 °C |
digestion time: | COD is 10min | Temperature control time: | adjustable from 1 to 9999min |
Batch volume: | 4 water samples (or choose 16 water samples) | Optical stability: | the instrument absorbance value drifts less than 0.002A within 20min |
Power consumption: | current <40uA; digester power consumption: <65W | Weight: | Main unit 0.5kg;digestion instrument 1kg |
Dimensions: | measuring instrument 80mm*230mm*55mm;Digestion instrument 105mm*160mm*90mm | ||
Normal use conditions: | |||
Ambient temperature: | 5 to 40 ° C | Relative humidity: | ≤85% |
Power supply: | Host: AA Battery*4 Digestion instrument: car cigarette lighter or 220V power supply (or optional battery power supply) | No significant vibration and electromagnetic interference, avoid direct sunlight. |
Measurement range: | COD: 5~2000mg/L, measured over dilution | Indication error: | COD: ≤ ± 5 % |
Repeatability: | ≤3% | Anti-chlorine interference: | ≤2000mg/L |
Temperature control accuracy: | ±1 °C | Temperature control system: | can be set at room temperature ~180°C, COD digestion temperature is 165 °C |
digestion time: | COD is 10min | Temperature control time: | adjustable from 1 to 9999min |
Batch volume: | 4 water samples (or choose 16 water samples) | Optical stability: | the instrument absorbance value drifts less than 0.002A within 20min |
Power consumption: | current <40uA; digester power consumption: <65W | Weight: | Main unit 0.5kg;digestion instrument 1kg |
Dimensions: | measuring instrument 80mm*230mm*55mm;Digestion instrument 105mm*160mm*90mm | ||
Normal use conditions: | |||
Ambient temperature: | 5 to 40 ° C | Relative humidity: | ≤85% |
Power supply: | Host: AA Battery*4 Digestion instrument: car cigarette lighter or 220V power supply (or optional battery power supply) | No significant vibration and electromagnetic interference, avoid direct sunlight. |