TS-1300U
TOP
TS-1300U Vertical Laminar Flow Clean Bench is a laboratory instrument used for providing a clean and sterile work environment for handling materials that are sensitive to contamination. They are preferred over traditional methods of handling sensitive materials because they provide a safe and controlled environment for the user and the surrounding environment.
Characteristic:
Arbitrary positioning sliding door system is adopted.
The shell is welded with cold-rolled plate, the surface is electrostatically sprayed, and the work surface is. SUS304 brushed stainless steel, corrosion-resistant, easy to clean.
The lighting and sterilization system are interlocked safely, and have the function of timing the ultraviolet light.
Digital display LCD control interface, more humanized design.
The vertical quasi-closed table top and the formation of the downflow air curtain in the operating room can effectively prevent external air from being injected and clean the operating area.
It is equipped with a HEPA high-efficiency air filter and a primary filter for preliminary filtration, which can effectively prolong the service life of the high-efficiency filter.
TS-1300U Vertical Laminar Flow Clean Bench is a laboratory instrument used for providing a clean and sterile work environment for handling materials that are sensitive to contamination. They are preferred over traditional methods of handling sensitive materials because they provide a safe and controlled environment for the user and the surrounding environment.
Characteristic:
Arbitrary positioning sliding door system is adopted.
The shell is welded with cold-rolled plate, the surface is electrostatically sprayed, and the work surface is. SUS304 brushed stainless steel, corrosion-resistant, easy to clean.
The lighting and sterilization system are interlocked safely, and have the function of timing the ultraviolet light.
Digital display LCD control interface, more humanized design.
The vertical quasi-closed table top and the formation of the downflow air curtain in the operating room can effectively prevent external air from being injected and clean the operating area.
It is equipped with a HEPA high-efficiency air filter and a primary filter for preliminary filtration, which can effectively prolong the service life of the high-efficiency filter.
Cleaning level | Grade 100≥0.5μM (209E U.S. Federal) |
Number of bacteria | ≤5per utensil.hour (90mm utensil) |
The average wind speed | 0.25~0.45m/s |
Noise | ≤62dB (A) |
Half ventilation peak value | ≤0.5μm (XYZ direction) |
Illumination | ≥300LX |
Power supply | AC, 220V/50Hz |
Maximum power | 500W |
Weight | 150kg |
Dimension of working area (W1*D1*H1) | 1140*600*700mm |
Overall dimension (W*D*H) | 1300*760*1760mm |
Suited number | Double/Single |
Efficient filter specifications and quantities | 1125*540*50*① |
Specification and number of fluorescent lamp or UV lamp of ultraviolet lights | 12W*①/30W*① |
Cleaning level | Grade 100≥0.5μM (209E U.S. Federal) |
Number of bacteria | ≤5per utensil.hour (90mm utensil) |
The average wind speed | 0.25~0.45m/s |
Noise | ≤62dB (A) |
Half ventilation peak value | ≤0.5μm (XYZ direction) |
Illumination | ≥300LX |
Power supply | AC, 220V/50Hz |
Maximum power | 500W |
Weight | 150kg |
Dimension of working area (W1*D1*H1) | 1140*600*700mm |
Overall dimension (W*D*H) | 1300*760*1760mm |
Suited number | Double/Single |
Efficient filter specifications and quantities | 1125*540*50*① |
Specification and number of fluorescent lamp or UV lamp of ultraviolet lights | 12W*①/30W*① |