Availability: | |
---|---|
Quantity: | |
ZDDN-9830A
TOP
products produced can be replaced with the "special operating system for the determination of chemical fertilizers and compound fertilizers. After replacing the system, add "HF" at the end of the existing product model. The products all comply with: "GB/T8572-2010" , "GB/T17767.1-2008", "NY/T1977-2010", "NY-T1116-2014"... regarding "In the presence of methyl red-methylene blue mixed indicator solution, use sodium hydroxide standard titrant to return titration" standard.
Characteristic:
Input the titration volume and automatically calculate the analysis results and store, display, query, and print them. It has some functions of a fully automatic product.
The instrument has a built-in protein coefficient lookup table for users to read, query and participate in system calculations.
Shut down and automatically clean the alkali pipeline to prevent pipeline blockage and ensure liquid supply accuracy.
products produced can be replaced with the "special operating system for the determination of chemical fertilizers and compound fertilizers. After replacing the system, add "HF" at the end of the existing product model. The products all comply with: "GB/T8572-2010" , "GB/T17767.1-2008", "NY/T1977-2010", "NY-T1116-2014"... regarding "In the presence of methyl red-methylene blue mixed indicator solution, use sodium hydroxide standard titrant to return titration" standard.
Characteristic:
Input the titration volume and automatically calculate the analysis results and store, display, query, and print them. It has some functions of a fully automatic product.
The instrument has a built-in protein coefficient lookup table for users to read, query and participate in system calculations.
Shut down and automatically clean the alkali pipeline to prevent pipeline blockage and ensure liquid supply accuracy.
Project | Parameter | Project | Parameter | |
Analysis scope | 0.1-240 mgN | Communication Interface | 232 / Cooling water / Reagent barrel level | |
Accuracy(RSD) | ≤0.5% | Digestion tube waste discharge mode | Manual/automatic discharge | |
Recovery rate | 99-101% | Steam flow regulation | 1%--100% | |
Distillation time | 10-9990 free setting | Safe alkali addition mode | 0-99 seconds | |
Sample analysis time | 4-8min/(cooling water temperature 18℃) | Automatic shutdown time | 60 minutes | |
Titrant concentration range | 0.01—5mol/L | Operating Voltage | AC220V/50Hz | |
Touchscreen | 10-inch color LCD touch screen | Heating power | 2000W | |
Data storage capacity | 1 million sets of data | Host size | Length: 500* Width: 460* Height: 710mm | |
Printer | 5.7CM thermal automatic cutting printer |
Project | Parameter | Project | Parameter | |
Analysis scope | 0.1-240 mgN | Communication Interface | 232 / Cooling water / Reagent barrel level | |
Accuracy(RSD) | ≤0.5% | Digestion tube waste discharge mode | Manual/automatic discharge | |
Recovery rate | 99-101% | Steam flow regulation | 1%--100% | |
Distillation time | 10-9990 free setting | Safe alkali addition mode | 0-99 seconds | |
Sample analysis time | 4-8min/(cooling water temperature 18℃) | Automatic shutdown time | 60 minutes | |
Titrant concentration range | 0.01—5mol/L | Operating Voltage | AC220V/50Hz | |
Touchscreen | 10-inch color LCD touch screen | Heating power | 2000W | |
Data storage capacity | 1 million sets of data | Host size | Length: 500* Width: 460* Height: 710mm | |
Printer | 5.7CM thermal automatic cutting printer |