ZDDN-9870
TOP
products produced can be replaced with the "special operating system for the determination of chemical fertilizers and compound fertilizers. After replacing the system, add "HF" at the end of the existing product model. The products all comply with: "GB/T8572-2010" , "GB/T17767.1-2008", "NY/T1977-2010", "NY-T1116-2014"... regarding "In the presence of methyl red-methylene blue mixed indicator solution, use sodium hydroxide standard titrant to return titration" standard.
Characteristic:
The system automatically shuts down after 60 minutes of unattended operation, which is energy-saving, safe and secure.
The instrument has a built-in protein coefficient query table for users to read, query and participate in system calculations. When the coefficient = 1, the analysis result is "nitrogen content". When the coefficient > 1, the analysis result is automatically converted to "protein content" and displayed, stored and printed. .
The R, G and B three-color light intensity automatic adjustment system is suitable for the analysis of samples with different concentrations.
products produced can be replaced with the "special operating system for the determination of chemical fertilizers and compound fertilizers. After replacing the system, add "HF" at the end of the existing product model. The products all comply with: "GB/T8572-2010" , "GB/T17767.1-2008", "NY/T1977-2010", "NY-T1116-2014"... regarding "In the presence of methyl red-methylene blue mixed indicator solution, use sodium hydroxide standard titrant to return titration" standard.
Characteristic:
The system automatically shuts down after 60 minutes of unattended operation, which is energy-saving, safe and secure.
The instrument has a built-in protein coefficient query table for users to read, query and participate in system calculations. When the coefficient = 1, the analysis result is "nitrogen content". When the coefficient > 1, the analysis result is automatically converted to "protein content" and displayed, stored and printed. .
The R, G and B three-color light intensity automatic adjustment system is suitable for the analysis of samples with different concentrations.
Project | Parameter | Project | Parameter | |
Analysis scope | 0.1-240 mgN | Touchscreen | 7-inch color LCD touch screen | |
Accuracy(RSD) | ≤0.5% | Data storage capacity | 1 million sets of data | |
Recovery rate | 99-101% | Printer | 5.7CM thermal automatic cutting printer | |
Minimum titration volume | 0.2μL/step | Safe alkali addition mode | 0-99 seconds | |
Titration speed | 0.05-1.0ml/S optionally set | Automatic shutdown time | 60 minutes | |
Distillation time | 10-9990 free setting | Operating Voltage | AC220V/50Hz | |
Sample analysis time | 4-8min/(cooling water temperature 18℃) | Heating power | 2000W | |
Titrant concentration range | 0.01—5mol/L | Host size | Length: 500* Width: 460* Height: 710mm | |
Titration cup volume | 300ml |
Project | Parameter | Project | Parameter | |
Analysis scope | 0.1-240 mgN | Touchscreen | 7-inch color LCD touch screen | |
Accuracy(RSD) | ≤0.5% | Data storage capacity | 1 million sets of data | |
Recovery rate | 99-101% | Printer | 5.7CM thermal automatic cutting printer | |
Minimum titration volume | 0.2μL/step | Safe alkali addition mode | 0-99 seconds | |
Titration speed | 0.05-1.0ml/S optionally set | Automatic shutdown time | 60 minutes | |
Distillation time | 10-9990 free setting | Operating Voltage | AC220V/50Hz | |
Sample analysis time | 4-8min/(cooling water temperature 18℃) | Heating power | 2000W | |
Titrant concentration range | 0.01—5mol/L | Host size | Length: 500* Width: 460* Height: 710mm | |
Titration cup volume | 300ml |